Belgium - Overview information
It includes overview information for Belgium regarding the current state of implementation for each article of Directive 2002/91/EC. Further information for each article is available.
Table of Contents
The implementation of the EPBD varies in the different Belgium regions.
Information from EPBD concerted action - Sept. 2005
Procedures: regional
Covered building types: new buildings (residential, offices, schools)
Assessment method: asset rating
Published as standard: will be published in law (ordinance)
Use of CEN standards: pragmatic use, possible integration at later term
Regulation: regional (same for residential and non residential)
Moment of compliance checking or reporting: after works
Type of requirements: U-value + average insulation level + EP level + possibly extra performance requirements for some kind of equipment
Role of renewables: to be included in the feasibility study as per article5
Regulation: regional
Building types: dwellings, offices, public buildings, schools
Moment for according certificate: after completion
Quality check of the input data: included
Compliance checking includes: total performance, insulation, etc...
Procedures: regional
Covered building types: new buildings, residential, offices, schools
Assessment method: asset rating (except public buildings: operational)
Published as standard: published as an attachment of an order
Use of CEN standards: pragmatic use, further integration at later term
Regulation: regional. Same Energy Performance level for dwellings, offices and schools but different calculation methods
Moment of compliance checking or reporting: after works
Type of requirements: U-value + average insulation level + EP level + ventilation
Role of renewables: integrated in the calculation method
Regulation: regional
Building types: dwellings, offices and schools
Energy types: primary energy
Moment for according certificate: after completion
Quality check of the input data: sent to a governmental database for random check
Compliance checking includes: all requirements
Procedures: regional
Covered building types: new buildings residential, public, existing stock
Assessment method: asset, benchmark, operational
Published as standard: no (ordinance)
Use of CEN standards: integration at later term
Regulation: regional, same for residential and non residential
Moment of compliance checking or reporting: 2 levels, before and after works
Type of requirements: U-value + average insulation level + EP level + ventilation
Role of renewables: to be included in the feasibility study as per article5
Regulation: regional
Building types: dwellings, offices, public buildings, schools
Moment for according certificate: after completion
Quality check of the input data: included
Compliance checking includes: total performance, insulation, etc...